Page 6 - Manual – Gas patio heater G21 – Inferno
P. 6

Gas requirements
          Use LPG, propane, butane or propane/butane mixture gas tanks only.
          Maximum inlet pressure of propane regulator must not exceed 100 PSI.
          The installation must conform to local standards. In the absence of these standards it must
          conform the standard for storage and handling liquid petroleum gases.
          A dented, rusty or damaged tank may be hazardous and should be checked by your tank supplier.
          Never use a tank with damaged valve connection.
          The tank must be arranged to provide for vapor withdrawal from the operating cylinder.
          Never connect an unregulated tank to this appliance.
          Leakage test
             Gas connections on the heater are leak tested at the factory prior to shipment. A complete
             gas tightness check must be performed at the installation site due to possible mishandling
             in shipment or excessive pressure being applied to the heater.
            •  Make a soap solution of one part liquid detergent and one part water. The soap solution can
             be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
            •  The heater must be checked with a full cylinder.
            •  Make sure the safety control valve is in the OFF position.













             •  Turn the gas supply ON.
             •  In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas
              supply on and recheck.
             •  Never leak test while smoking.
             •  Any gas odor should be signal for you undertake safety steps while being careful.
             •  Do not do anything that could lead to open flame (don’t use matches. lighters, etc.) and do
              not touch electric sockets/switchgears.

           Operation and storage
           To turn on the appliance:
            1.  Turn on the valve on the gas supply cylinder completely.
            2.  Push the control knob in and turn it to „PILOT“ position.
            3.  Press and hold the control knob for 90 seconds. To light the pilot flame, press the IGNITION
              button several times after 60 seconds, until blue light shows. Once the light is constant,
              release the control knob button and set your desired temperature.
             •  If a new tank has been connected, please allow the air to purge out through the pilot hole for
              at least a minute.
             •  When lighting the pilot flame, make sure the variable control knob is continuously pressed
              down while pressing the ignition button.