Troubleshooting
Symptoms Possible reason Solution
The dehumidifier does • Power plug fell out. • Insert the plug into socket.
not run. • Water tank full of water • Drain the water tank and
or place dat incorrect place it back in correctly.
position. (FL)
• The ambient temperatur • Normal phenomenon.
eis lower than 5 °C or
higher than 32 °C. (LO/HI)
The dehumidification • Room temperature or • In dry seasons the
function is not effective. humiditiy too low. dehumidification ability will
reduce.
• Air outlet and inlet • Clean up the object block the
blocked. air outlet and inlet.
Air is not blown out. • Air filter blocked. • Clean the air strainer.
Noise is abnormal • Appliance placed • Place the appliance on a firm
during operation. improperly so that i tis level place.
inclined or unstable.
• Air strainer blocked. • Clean the air strainer.
• „Tittering“ sound. • The flowing sound of
refrigerant, a normal
phenomenon.
Water leakage • Connection of drainage • Fasten drainage pipe.
pipe becomes loose.
• Drainage system is • Remove obstacles and
blocked. straighten out the waterpipe.
Frosting occurs • The ambient temperature • It is a normal phenomenon
is low and i tis in the state and the appliance has the
of waiting to defrost. (P1) automatic defrosting function.
LC error • The child lock is on. • Press and hold the M button
for 3 seconds.
Display code – Instruction
E1 – The coil sensor detects anomaly
E2 – The room temperature sensor detects anomaly
CL – The unit is in the internal drying state, normal