Operating methods
        Setting the timer off
        When the dehumidifier is running, press the TIMER button to adjust time from 1 to 24 hours.
        Press the button once to increase the setting by 1 hour – after the set time exceeds 24 hours,
        the figure returns back to 1 hour. The TIMER button can also be pressed at any time needed,
        the time increases or decreases circularly. When the time expires, the appliance turns OFF
        automatically. After the setting is completed, if the TIMER button does not act at all within
        5 seconds, the set time is confirmed. In timer off state the key lamp on the TIMER button is ON.
        Setting of timer on
        When the dehumidifer is in standby mode, the method for adjustment of setting time by the
        TIMER button is the same as timer off. After the setting is completed, if the TIMER button does
        not act at all within 5 seconds, the set time is confirmed. In timer off state the key lamp on the
        TIMER button is ON and the set time is displayed on control panel.

        AUTO mode
        Select AUTO dehumidification. If the room humidity is higher than the set humidity by + 5 %, the
        compressor will start and the fan will run at the set speed. If the room humidity is between + 5%
        or - 5% of the set humidity, the compressor and the fan will run at the set speed. If the room
        humidity is lower than the set humidity by - 5%, then the compressor will stop but the fan will run
        at the set speed. The default set humidity value is 50%.
        CONTINUOUS mode
        Select CONTINUOUS dehumidification, no matter how the relative humidity in the room is,
        the compressor starts, the fan runs at high speed in default setting and the air speed can be
        regulated via the air speed button.
        DRYING function
        Press the DRYING button to start the drying process. The appliance starts at HIGH air speed and
        releases air continuously for 30 minutes. The appliance turns to run at LOW air speed and lasts
        for 20 minutes.
        To stop, press the DRYING button again to cancel the process and recover to the prior running
        mode. Or, press the POWER button to stop the process and recover to standby mode.

        Humidity indicate function
        Press the humidity setting button and the mode button at the same time to turn ON/turn OFF
        the humidity light indicator. When the machine works, the color of light belt on the front cover
        will change with humidit level. Red color show humidity over 60 %, green color shows humidity
        40-60 % and blue color shows less than 40 % humidity.

        Pump function
        Press the humidity setting for 3 seconds to turn on/off the pump function (connect the drainage
        pipe before turning the on the pump function).
        Air-swing function
        Press the Timer button and the Drying button at the same time to start or end the Air-swing
        function.
        Water drainage
        When the water tank is full, the full water icon on LCD display flashes (the compressor, fan and
        negative ion will stop running), the buzzer sounds 10 times to remind the user till the water is
        drained.