Page 14 - Manual – Dehumidifier G21 – Impact 40, 50
P. 14

•  refrigerating pipe or components are installed in a position where they are unlikely to be
            exposed to any substance which may corrode refrigerant containing components, unless
            the components are constructed of materials which are inherently resistant to being
            corroded or are suitably protected against being so corroded.
        Checks to electrical devices
        Repair and maintenance to electrical components shall include initial safety checks and
        component inspection procedures. If a fault exists that could compromise safety, then no
        electrical supply shall be connected to the circuit until it is satisfactorily dealt with
        Initial safety checks shall include:
          •  that capacitors are discharged: this shall be done in a safe manner to avoid possibility of
            sparking;
          •  that no live electrical components and wiring are exposed while charging, recovering or
            purging the system;
          •  that there is continuity of earth bonding.
        Repairs to sealed components
        During repairs to sealed components, all electrical supplies shall be disconnected from the
        equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely
        necessary to have an electrical supply to equipment during servicing, then a permanently
        operating form of leak detection shall be located at the most critical point to warn of a potentially
        hazardous situation.
        Particular attention shall be paid to the following to ensure that by working on electrical
        components, the casing is not altered in such a way that the level of protection is affected. This
        shall include damage to cables, excessive number of connections, terminals not made to original
        specification, damage to seals, incorrect fitting of glands, etc.
        Ensure that seals or sealing materials have not degraded to the point that they no longer serve
        the purpose of preventing the ingress of flammable atmospheres.  Replacement parts shall be in
        accordance with the manufacturer’s specifications.
        Repair to intrinsically safe components
        Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that
        this will not exceed the permissible voltage and current permitted for the equipment in use.
        Intrinsically safe components are the only types that can be worked on while live in the presence
        of a flammable atmosphere. Replace components only with parts specified by the manufacturer.
        Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
        Cabling
        Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp
        edges or any other adverse environmental effects. The check shall also take into account the
        effects of aging or continual vibration from sources such as compressors or fans.

        Detection of flammable refrigerants
        Under no circumstances shall potential sources of ignition be used in the searching for or
        detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not
        be used.

        Removal and evacuation
        When breaking into the refrigerant circuit to make repairs – or for any other purpose –
        conventional procedures shall be used. However, for flammable refrigerants it is important that
        best practice is followed since flammability is a consideration.