Page 6 - Manual – Dehumidifier G21 – Impact 20, 30
P. 6

Operating methods
          Setting the timer off
          When  the  dehumidifier  is running,  press  the  TIMER  button  to  adjust  time  from  1  to  24  hours.
          Press the button once to increase the setting by 1 hour – after the set time exceeds 24 hours, the
          figure returns back to 1 hour. When the time expires, the appliance turns OFF automatically. After
          the setting is completed, if the TIMER button does not act at all within 5 seconds, the set time is
          confirmed. In timer off state the key lamp on the TIMER button is ON.

          Setting of timer on
          When the dehumidifer is in standby mode, the method for adjustment of setting time by the
          TIMER button is the same as timer off. After the setting is completed, if the TIMER button does
          not act at all within 5 seconds, the set time is confirmed. In timer off state the key lamp on the
          TIMER button is ON and the set time is displayed on control panel.

          AUTO mode
          Select AUTO dehumidification. If the room humidity is higher than the set humidity by+ 5% the
          compressor will start and the fan will run at the set speed. If the room humidity is between + 5%
          or - 5% of the set humidity, the compressor and the fan will run at the set speed. If the room
          humidity is lower than the set humidity by - 5%, then the compressor will stop but the fan will run
          at the set speed. The default set humidity value is 50%.
          CONTINUOUS mode
          Select CONTINUOUS dehumidification, no matter how the relative humidity in the room is,
          the compressor starts, the fan runs at high speed in default setting and the air speed can be
          regulated via the air speed button.

          DRYING function
          Press the DRYING button to start the drying process. The appliance starts at HIGH air speed and
          releases air continuously for 30 minutes. The appliance turns to run at LOW air speed and lasts
          for 15 minutes.
          To stop, press the DRYING button again to cancel the process and recover to the prior running
          mode. Or, press the POWER button to stop the process and recover to standby mode.
          Humidity indicate function
          Press the humidity setting button and the mode button at the same time to turn ON/turn OFF
          the humidity light indicator. When the machine works, the color of light belt on the front cover
          will change with humidit level. Red color show humidity over 60 %, green color shows humidity
          40-60 % and blue color shows less than 40 % humidity.
          Water drainage
          When the water tank is full, the full water icon on LCD display flashes (the compressor, fan will
          stop running), the buzzer sounds 10 times to remind the user till the water is drained.
            •  Place both hands respectively at the side of the back cover side of the depression, gently
             remove the water tank and open the tank cover on the right side of the body, then pour the
             water from the gap between water tank and the cover.
            •  Close the tank cover and rotate the water tank handle down, then put the water tank gently
             back in to restart the appliance.
          Attention: when the water tank is full of water, please empty it. Before putting the water tank into
   1   2   3   4   5   6   7   8   9   10   11