Page 11 - Manual – Dehumidifier G21 – Impact 20, 30
P. 11
G21 Smart Home app Safety instructions for installing the device using the R290 refrigerant
EN
Download the G21 Smart Home app from Google Play or App Store. gas
To avoid damage, place the unit in an upright position for at least 24 hours before initiation.
Make sure that the air outlet and air inlet are never blocked.
Only operate the unit on a horizontal surface to ensure no water leaks out.
Warnings
• Do not exceed impedance greeter than 0.236ohm in supply the appliance is connected to.
• Any person who is involved with working on or breaking into a refrigerant a refrigerant circuit
Pairing the app with the device should hold a current valid certificate from an industry-accredited assessment authority.
• Remember the environment when disposing of packaging around the appliance and when the
appliance has reached its by date.
Menu Choose the type of the
appliance you want to add Appliance connected! • A warning that the appliance shall be stored in a well-ventilated area where the size
The appliance Dehumidifier Impact is corresponds to the room area as specified for operation.
My appliance Sous vide Akura Connect to the WiFi ready to use. You can change the name
you want to add your of your appliance now
appliance to Name of the appliance • The appliance shall be stored so as to prevent mechanical damage from occurring.
Sous vide cookbook You’re connected to the Mojewifina WiFi. Dehumidifier G21 Impact – Home
Air conditioning Envi 12 H
If you want to add the appliance to this • Information for spaces where refrigerant pipes are allowed, including statements
WiFi, click continue.
G21 Vitality Otherwise, go to WiFi setting in your
Dehumidifier Impact » that the installation of pipe-work shall be kept to a minimum;
smartphone and connect to desired WiFi.
» that pipe-work shall be protected from physical damage and, in the case of flammable
Instagram G21 Vitality
refrigerants, shall not be installed in an unventilated space;
Manuals
» that compliance with national gas regulations shall be observed;
» that mechanical connections shall be accessible for maintenance purposes;
Add appliance Back WiFi setting Continue Finish
» that, for appliances containing flammable refrigerants, the minimum floor area of the room shall
be mentioned in the form of a table or a single figure without reference to a formula;
Click „Add Choose the Follow the Name your • A warning to keep any required ventilation openings clear of obstruction;
appliance“. appliance. instructions on the appliance and
screen. click „Finish“ • A notice that servicing shall be performed only as recommended by the manufacturer;
• When the portable air conditioner or dehumidifier is turned on, the fan can work continuously
Dehumidifier G21 Impact screen stable under normal conditions to provide the minimum air volume of 100m3/h even when the
compressor is closed due to the temperature controller.
• Use only implements recommended by the manufacturer for defrosting or cleaning
Power / Lock
„Low“ low power Locks the appliance’s • Do not perforate any of the components in the refrigerant circuit. Refrigerant gas may be
„High“ high power control panel. odourless
• Use care when storing the appliance to prevent mechanical faults.
/ Lamella Current humidity / Water drainage • Maintenance and repairs requiring the assistance of other qualified personnel must be carried
When switched on, the Install drainage hose out under the supervision of specialists in the use of inflammable refrigerants.
lamella starts moving. prior to turning this
function on.
/ Mode
Switching between „Auto“ Humidity
and „Continuous“ mode. Use to set desired
humidity.
CAUTION ON FIRE
/ Self-drying READ THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE
When switched on, the Plans Stop / Timer
appliance start the self- Turns on/off the R290 refrigerant gas complies with European environmental directives.
drying process. Plans appliance after set Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m2.
Turns on/off the time.