Page 5 - Manual – Gas Grill G21 – California BBQ
P. 5

Technical Information:
        T echnical Information:
         BRAND:               G21
         APPLIANCE CODE:      California BBQ
                              13.65 kW (993 g/h) The grill burner is dimensioned to 3.5 kW and
         THERMAL POWER        the side grill burner is dimensioned to 3.15 kW.
         GAS CATEGORY:        I3+(28-30/37)         I3B/P(30)
         GAS TYPES:           Butane      Propane   Butane, Propane or their mixture
         GAS PRESSURE:        28 - 30 mbar   37 mbar  30 mbar
                              Grill: 0.90 mm
         INJECTION JET SIZE:  Side: 0.85 mm
         IDENTIFICATION CODE:  2575DL0359CQ00453
         ONLY FOR OUTDOOR USE.
         WARNING: PARTS OF THE GRILL CAN BE VERY HOT. KEEP OUT OF REACH OF
         CHILDREN.
         BEFORE USE, PLEASE READ THE INSTRUCTION MANUAL CAREFULLY.



        Note:
        Diameter dimension of pan used for side burner, must be between 140-240mm
        Digits on the injector indicates its size, For example, ”0.85”on the injector means injector size is ”0.85mm”.
   1   2   3   4   5   6   7   8   9   10