Page 5 - Manual – Gas Grill G21 – California BBQ
P. 5
Technical Information:
T echnical Information:
BRAND: G21
APPLIANCE CODE: California BBQ
13.65 kW (993 g/h) The grill burner is dimensioned to 3.5 kW and
THERMAL POWER the side grill burner is dimensioned to 3.15 kW.
GAS CATEGORY: I3+(28-30/37) I3B/P(30)
GAS TYPES: Butane Propane Butane, Propane or their mixture
GAS PRESSURE: 28 - 30 mbar 37 mbar 30 mbar
Grill: 0.90 mm
INJECTION JET SIZE: Side: 0.85 mm
IDENTIFICATION CODE: 2575DL0359CQ00453
ONLY FOR OUTDOOR USE.
WARNING: PARTS OF THE GRILL CAN BE VERY HOT. KEEP OUT OF REACH OF
CHILDREN.
BEFORE USE, PLEASE READ THE INSTRUCTION MANUAL CAREFULLY.
Note:
Diameter dimension of pan used for side burner, must be between 140-240mm
Digits on the injector indicates its size, For example, ”0.85”on the injector means injector size is ”0.85mm”.