Page 8 - Manual – Gas patio heater G21 – Tornado
P. 8
Specifications
Technical details:
Appliance category: 3+(28-30/37) 3B/P(30) 3B/P(50) 3B/P(37)
Butane, Butane, Butane,
Type of gas: Butane Propane propane, propane, their propane, their
their mixture mixture mixture
28 - 30
Gas pressure: 37 mbar 30 mbar 50 mbar 37 mbar
mbar
Outlet pressure of the 30
regulator: mbar 37 mba 30 mbar 50 mbar 37 mbar
Thermal power: 13 kW (945 g/h)
Gas Pressure Main Opening Opening of Burner
280/300 2,0 mm 0,18
370 1,80 mm 0,18
500 1,80 mm 0,18
0063/21
Troubleshooting
Problem Possible cause Solution
Burner won’t light • Tank is frosted over • Wait until the tank warms up
• Blockage in orifice and is defrosted
• Control knob is not in ON • Clear blockage
position • Turn control knob to ON
Burner flame is low • Gas pressure is low • Turn tank valve OFF and
• Outdoor temperature is replace tank
less than 4ºC and tank is • Use a full tank
less than 1/4 full • Check burner and orifices for
• Control knob fully ON blockage
Carbon build-up • Dirt or film on reflector • Clean reflector and burner
Thick black smoke and burner screen screen
• Blockage in burner • Remove blockage and clean
burner inside and outside
The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.