Safety instructions for installing the device using the R290 refrigerant
        gas
        To avoid damage, place the unit in an upright position for at least 24 hours before initiation.
        Make sure that the air outlet and air inlet are never blocked.
        Only operate the unit on a horizontal surface to ensure no water leaks out.
        Warnings
          •  Do not exceed impedance greeter than 0.236ohm in supply the appliance is connected to.
          •  Any person who is involved with working on or breaking into a refrigerant a refrigerant circuit
            should hold a current valid certifi cate from an industry-accredited assessment authority.
          •  Remember the environment when disposing of packaging around the appliance and when the
            appliance has reached its by date.
          •  A warning that  the appliance  shall be stored in a well-ventilated  area where  the size
            corresponds to the room area as specifi ed for operation.
          •  The appliance shall be stored so as to prevent mechanical damage from occurring.
          •  Information for spaces where refrigerant pipes are allowed, including statements
           » that the installation of pipe-work shall be kept to a minimum;
           » that pipe-work shall be protected from physical damage and, in the case of fl ammable
          refrigerants, shall not be installed in an unventilated space;
           » that compliance with national gas regulations shall be observed;
           » that mechanical connections shall be accessible for maintenance purposes;
           » that, for appliances containing fl ammable refrigerants, the minimum fl oor area of the room shall
          be mentioned in the form of a table or a single fi gure without reference to a formula;
          •  A warning to keep any required ventilation openings clear of obstruction;
          •  A notice that servicing shall be performed only as recommended by the manufacturer;
          •  When the portable air conditioner or dehumidifi er is turned on, the fan can work continuously
            stable under normal conditions to provide the minimum air volume of 100m3/h even when the
            compressor is closed due to the temperature controller.
          •  Use only implements recommended by the manufacturer for defrosting or cleaning
          •  Do not perforate any of the components in the refrigerant circuit. Refrigerant gas may be
            odourless
          •  Use care when storing the appliance to prevent mechanical faults.
          •  Maintenance and repairs requiring the assistance of other qualifi ed personnel must be carried
            out under the supervision of specialists in the use of infl ammable refrigerants.







                                  CAUTION ON FIRE
        READ THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE
        R290 refrigerant gas complies with European environmental directives.
        Appliance shall be installed, operated and stored in a room with a fl oor area larger than 4 m2.
   6   7   8   9   10   11   12   13   14   15   16