Page 11 - Manual – Dehumidifier G21 – Impact 20
P. 11

Additional warning for appliance with R290 refrigerant gas (refer to the rating plate
        for the type of refrigerant gas used)
         1.  Checks to the area
        Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary
        to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following
        precaution shall be completed prior to conducting work on the system.
         2.  Work procedure
        Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable
        gas or vapour being present while the work is being performed.
         3.  General work area
        All maintenance staff and others working in the local area shall be instructed on the nature of work
        being carried out. Work in confined spaces shall be avoided.
         4.  Checking for presence of refrigerant
        The area shall be checked with an appropriate refrigerant detector prior to and during work, to
        ensure the technician is aware of potentially toxic or flammable atmospheres. Ensure that the
        leak detection equipment being used is suitable for use with all applicable refrigerants, i.e. non-
        sparking, adequately sealed or intrinsically safe.
         5.  Presence of fire extinguisher
        If any hot work is to be conducted on the refrigerating equipment or any associated parts,
        appropriate fire extinguishing equipment shall be available to hand.  Have a dry powder or CO2
        fire extinguisher adjacent to the charging area.
         6.  No ignition sources
        No person carrying out work in relation to a refrigerating system which involves exposing any
        pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or
        explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far
        away from the site of installation, repairing, removing and disposal, during which refrigerant can
        possibly be released to the surrounding space. Prior to work taking place, the area around the
        equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.
         7.  Ventilated area
        Ensure that the area is in the open or that it is adequately ventilated before breaking into the
        system or conducting any hot work. A degree of ventilation shall continue during the period that
        the work is carried out.
         8.  Checks to the refrigerating equipment
        Where electrical components are being changed, they shall be fit for the purpose and to the correct
        specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.
        If in doubt, consult the manufacturer’s technical department for assistance.
        The following checks shall be applied to installations using flammable refrigerants:
          •  the actual refrigerant charge is in accordance with the room size within which the refrigerant
            containing parts are installed;
          •  the ventilation machinery and outlets are operating adequately and are not obstructed;
          •  if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the
            presence of refrigerant;
          •  marking to the equipment continues to be visible and legible. Markings and signs that are
            illegible shall be corrected;
          •  refrigerating pipe or components are installed in a position where they are unlikely to be
            exposed to any substance which may corrode refrigerant containing components, unless the
            components are constructed of materials which are inherently resistant to being corroded or
            are suitably protected against being so corroded.
   6   7   8   9   10   11   12   13   14   15   16