Connecting the gas cylinder to the grill
This appliance is only suitable for use with low-pressure butane or propane gas or LPG mixtures,
fi tted with the appropriate low-pressure regulator via a fl exible hose. The hose should be secured
to the regulator and the appliance with hose clips. For barbecue which is set to I3B/P(30), I3+(28-
30/37) use a regulator which operates butane gas at 30 mbar and propane gas at 37 mbar. For
I3B/P(50), a regulator operates the butane, propane gas mixture at 50mbar. Ensure the regulator
was certifi ed by standard EN16129. Never store gas cylinder inside the grill.
Regulator and Hose
Use only regulators and hose approved for LP Gas at the above pressures. The life expectancy of
the regulator is estimated as 2 years. It is recommended that regulator is changed within 2 years of
the date of manufacture. The use of the wrong regulator or hose is unsafe; always check that you
have the correct items before operating the barbecue. The hose used must conform to the relevant
standard for the country of use. The length of the hose must be 1.5 metres (maximum). Worn or
damaged hose must be replaced. Ensure that the hose is not obstructed, kinked, or in contact
with any part of the barbecue other than at its connection.
Storage of Appliance
Storage of an appliance indoors is only permissible if the cylinder is disconnected and removed
from the appliance. When the appliance is not to be used for a period of time it should be stored
in its original packaging and stored in a dry dust free area.
Gas Cylinder
The gas cylinder should not be dropped or handled roughly! Always keep the cylinder in upright
position. during operation. Make sure the cylinder is from any source of fl ame before you change
the cylinder. If the appliance is not in use, the cylinder must be disconnected. Replace the
protective cap on the cylinder after disconnecting the cylinder from the appliance. The gas cylinder
must be sited outside the body of the appliance.
Cylinders must be stored outdoors in an upright position and out of the reach of children. The
cylinder must never be stored where temperatures can reach over 50°C. Do not store the cylinder
near fl ames, pilot lights or other sources of ignition. DO NOT SMOKE.
This barbecue is designed for use outdoors, away from any fl ammable materials. It is important
that there are no overhead obstructions and that there is a minimum distance of 3 m from the
side or rear of the appliance. It is important that the ventilation openings of the appliance are
not obstructed. The barbecue must be used on a level, stable surface. The appliance should be
protected from direct draughts and shall be positioned or protected against direct penetration by
any trickling water (e.g. rain).
Parts sealed by the manufacturer or his agent must not be altered by the user. No modifi cations
should be made to any part of this barbecue and repairs and maintenance should only be carried
out by a registered service engineer.
Since this barbecue has no restriction in the Emission of unburned gas, this barbecue must be
Since this barbecue has no restriction in the Emission of unburned gas, this barbecue must be
installed and/or used outdoors or in an amply ventilated area.
installed and/or used outdoors or in an amply ventilated area.