Page 8 - Manual – Gas gril G21 – Argentina BBQ
P. 8

Appliance connection
        Before connection, ensure that there is no debris caught in the head of the gas cylinder, regulator,
        burner and burner ports.  Spiders and insects can nest within and clog the burner/venturi tube at
        the orifice.  A clogged burner can lead to a fire beneath the appliance.
        Fit the hose to the appliance using a spanner to tighten it onto the connection thread.  If the hose is
        replaced it must be secured to the appliance and regulator connections with hose clips.  Disco-
        nnect the
        regulator from the cylinder (according to the directions supplied with the regulator) when the bar-
        becue is not in use.
        The Barbecue must be used in a well ventilated area.   Do not obstruct the flow of combustion air
        to the burner when the barbecue is in use.  GRILL CAN ONLY BE USED OUTDOOR.



                              BEFORE USE CHECK FOR LEAKS.

            NEVER CHECK FOR LEAKS WITH A NAKED FLAME, ALWAYS USE A SOAPY WATER
                                       SOLUTION.



        To check for leaks
        •  Make 2-3 fluid ounces of leak detecting solution by mixing one part washing up liquid with 3
          parts water.
        •  Ensure the control valve is “OFF”.
        •  Connect the regulator to the cylinder and ON/OFF valve to the burner, ensure the connections
          are secured then turn ON the gas.
        •  Brush the soapy solution onto the hose and all joints.  If bubbles appear you have a leak, which
          must be rectified before use.
        •  Retest after fixing the fault.
        •  Turn OFF the gas at the cylinder after testing.
        •  If leakage is detected and cannot be rectified.  Do not attempt to cure leakage but contact your
          gas dealer.
   3   4   5   6   7   8   9   10   11   12   13